🏛️ Tenement & Housing Fabric Preservation in This Territory
Properties across this region feature historical solid masonry, lath-and-plaster partitioning, and ornate plaster cornices. Our dedicated rewiring teams route low-smoke zero-halogen (LSZH) twin-and-earth cables under subfloors and down structural cavities, completely eliminating the need to score or compromise decorative ceilings.
DNO Communitry Intakes & 100A Modernisation
Many flatted dwellings in this region are supplied via communal cast-iron service heads installed in common entryways. Where existing 60A cutouts require upgrading to 100A PME to accommodate high-draw appliances, induction hobs, or EV chargers, Flexicomm coordinates directly with the regional Distribution Network Operator (DNO).
Scottish Building Standards Schedule 3 Warrant Exemption
Under Schedule 3 of the Building (Scotland) Regulations, like-for-like domestic rewiring is exempt from requiring a formal local council building warrant, provided work is carried out by an accredited approved contractor under BS 7671:2018+A2:2022. We issue full SELECT / 18th Edition certification directly to your solicitor or local authority upon completion.